V1.05:
Symptoms:
1. When the MPC2000XL loads a binary file (.BIN) that is not
for the MPC2000XL (e.g. operating system for S5000 or MPC2000), the operating
system stored in flashROM may be damaged. This will cause the message "Insert
MPC2000XL disk" to appear on the LCD, indicating that the operating system
has been corrupted. - fixed
2. In MONO sampling mode if sampling is stopped
by pressing STOP, incorrect data is added to the end of the sample. For example,
setting the record time to 10 sec. and stopping the recording at 6 sec. will
produce a 10sec. sample with incorrect data added to the end of the sample -
fixed
V1.06:
Symptoms:
1. When using the MPC2000XL as MMC Master and locked to external
time code (MTC) the MPC does not start properly. When the MPC is started it
sends PLAY and LOCATE commands. The connected recorder would begin playback
but stop upon receiving a LOCATE command. - Fixed
2.When slaving to SMPTE/MTC with the Start Time set to 1 hour
(in the Time Display page), the MPC does not sync to external time code correctly.
- Fixed
3. While slaving to external time code (SMPTE or MTC) while in
Song Mode, the MPC doesnt lock properly to the master machine. - Fixed
4. If the MPC received a Start command (MIDI Clock) it would
start from the beginning of the selected step rather than from the beginning
of step 1. - Fixed
5. When the MPC is set to sync to external time code while in
Song Mode with LOOP ON (main screen), with the Time Display set to HOURS, MINUTE,
SEC mode, the NOW time of the sequence displays the time of the individual sequence
rather than the value for the entire song. - Fixed
6. Tempo may be shown incorrectly in Song Mode.
- Fixed
7. If a sequences parameters (only) were copied to another sequence,
and that sequence was copied again, the final resulting sequence would contain
incorrect data. - Fixed
8. When you COPY BARS to a new sequence, then decrease the number
of bars with CHANGE BARS, the MPC hangs up. - Fixed
9. When the Note Variation setting is changed during
SONG playback, the sequence may be corrupted. - Fixed
10. When saving a copy of the operating system to a disk with
insufficient space, the save operation ended without a warning. - Fixed
11. When the MPC2000XL loads .ALL
files from MPC60 disks, it hangs. - Fixed
12. Loading sequences created on the MPC3000 and
larger than 280KB may cause the MPC2000XL to hang. - Fixed
V1.07:
Improvements:
1. Note selection via MIDI is supported for ERASE,
Timing Correct and Edit Velocity on MIDI tracks.*
* Note1: Note
selection is global and applied to all of the above functions. You cannot assign
a note range for ERASE and a separate setting for EDIT.
* Note2: Note
selection is always active. This allows the note range to be selected on the
Main screen before entering the desired mode.
* Note3: To
select note range, hold down one note while selecting the second note.
2. Note Variation Slider assignment can be changed while a sequence
is in Play/Record.
3. When Note Variation is assigned, the 16-LEVELS function is
automatically disabled.
4. The AFTER key can now be used in SONG and NEXT SEQ modes.
5. In STEP EDIT the Metronome is now turned on to assist with
the proper duration of PAD/MIDI note data.
6. TRANSPOSE is now supported in SONG/NEXT SEQ modes.
7. When transposing a track (SHIFT-MISC./TRANS) it applies to
the entire track regardless of the range assigned in the FIX field.
Corrections:
1. When 'Timing:' field is changed during recording,
the recorded notes may move to different clock ticks. - fixed.
2. After the NOTE REPEAT key is locked with the
SHIFT key, the first tap on a pad is not quantized. - fixed.
3. After using the COPY BARS function the MPC2000XL
may freeze. - fixed.
4. If you exit from the NEXT SEQ screen without using the NEXT
SEQ function, TRACK MUTE, VEL % and TEMPO CHANGE do not work properly in MAIN
or TRACK MUTE screens - fixed.
5. In SONG mode, setting the Tempo Source to MASTER may cause
the MPC2000XL to improperly slave to incoming MTC. -
fixed.
6. When saving Standard MIDI Files, the duration
is saved incorrectly if the note duration is longer than the sequence. -fixed.
7. Improved disk handling, including support for APS/PGM files
that span multiple floppies, MPC60/MPC3000 sequence
files that contain more than 64 tracks, Master Tempo settings
from MPC2000 disks and Track Mutes from MPC60/MPC3000 sequence files -
fixed.
8. Internal sound is muted if SOFT THRU is not set to "AS TRACK" -
fixed
V1.10:
Improvements:
1. Added support for 1024 byte/sector and 2048 byte/sector SCSI
media used by many MO drives. It's now possible to use 3.5 inch 640 MB MO drives,
5.25 inch MO drives and DVD-ROM drives. DVD-ROM support provides the same functionality
as a CD-ROM drive.
Corrections:
1. Lock-up problem that caused that Debug page to appear after
using "Copy bar" many times, or using "Change bar" and decreasing
the number of bars with the Jog wheel. -
fixed
2. "Wrong Disk" message appears when .APS and/or .PGM
files that span multiple 2DD MPC60/MPC3000 formatted disks are loaded. -
fixed.
3. When loading programs and sounds that are spanned across multiple
disks are loaded some sounds on the second disk would not be assigned to their
programs. - fixed.
4. Events copied get erased when the sequence is
changed and reselected immediately after Copy Track -
fixed.
5. Files from SCSI removable media (such as Zip disks) could
not be loaded if the disk was saved just after changing from another disk that
had been saved to. The MPC2000XL would display "Wrong file format"
- fixed
6. Improved sync when the MPC2000XL is set to MTC slave from
one machine while also set to MTC master to drive a second machine. After several
Locate/Play combinations that MPC2000XL may begin outputting incorrect MTC.
- fixed.
7. Sequence data could be lost if a MIDI file was loaded and
then immediately going to MIXER or PROGRAM mode without going to MAIN mode first.
- fixed
8. Assigning Note VariationSlider to 'ctrl change'
was not effective - fixed
V1.11
Corrections:
1. Long Disk Save Times - V1.10 slowed the performance
of disk saves. V1.11 has improved the performance back to the same level of
performance of the V1.07 release - fixed
2. Internal drum sounds and MIDI event data would stop during playback of
a sequence when the Tempo is quickly changed with the jog Wheel. The sequence
appears to keep playing (counter continues) and MIDI Clock/MTC is still being
output. - fixed.
3. The incorrect tick number (-1) was set on the Now: field in Step mode
when set with the 10 key. -fixed.
V1.12
Corrections:
1. "Erase All Off Tracks" (Move cursor to track on/off field and press
OPEN WINDOW) might not work correctly. Tracks erased using this method become
"unused" but may still contain data. - fixed
2. Samples with a "space" at the beginning of the name could not be
loaded. - fixed
3. Hi-hat decay data from MPC60/MPC60-II sequences cold not be loaded correctly.
- fixed
4. A song could not sync properly as a MTC slave device after locating to the
end of the song. - fixed
5. After converting a sequence to a song, the song may not start playback when
slaved to MTC. -fixed
6. A song may sometimes take a long time to start playback in MTC master mode.
- fixed
7. The internal timing of a sequence may contain a slight inaccuracy when playing
in loop mode due to a miscalculation of the loop point (less than 1 msec.) Short
sequences playing in loop mode may drift out of sync if playing for longer periods.
- fixed
8. "Error at xxxx:xxxx" may appear and lock up during save functions
on some defective disks. -fixed
9. When updating the operating system, a "Completed" message may appear
even though the system was not properly updated. - fixed
V1.14
[Corrections]
1. Zip disk data corruption - fixed
On MPC2000XL's with an ATAPI Zip disk installed internally, the data on the
Zip disk may be occasionally damaged. This may happen when the drive is in sleep
mode and and does not cor-rectly wake up when a disk operation (save or load),
or a disk write operation (save, rename, over-write, erase, etc.) is performed.
The wait time for the restart of the Zip disk in V1.12 OS is set to 3 sec. However
the Zip disk may not restart within this time period, causing a timeout. In
this case the next write operation may damage the contents of the disk. In V1.14,
the wait time has been extended from 3 sec to 20 sec.
2. Song conversion problem - fixed
A Song may not be properly converted to a sequence if one of the sequences in
the song has a large number of events (over 768 notes) and is repeated more
than twice in the song.
3. Song conversion problem - fixed
A song may not be properly converted to a sequence if the sequence contains
MIDI system exclu-sive messages and the track containing those messages is set
to OFF, and the option of "OFF TRACKS IGNORED" or "MERGED ON
MIDI CH" is selected in the song convert options.
4. MTC Slave problem - fixed
In MTC slave mode a song may play at an unstable tempo at the point where a
sequence changes to the next sequence if the song contains several sequences
with different tempos.
5. Edit range problem - fixed
In EDIT mode, the time range cannot be set correctly after pressing TC (F1)
in STEP EDIT mode.